Product overview ICAF

ICAF/MGPS power unit for growth prevention in box coolers, open cooling systems and strainers using copper anodes. The controller has a self-testing and calibrating microprocessor. System will be operated by an external LCD touchscreen. The unit’s output can be adjusted with presets to suit operational conditions. It can interact with seawater pumps to save anode material.

General  
Article code MAGIC 3
Description MGPS systems
Mounting type Wall mounted
Total weight (kg) About 23 kg
Cabinet dimensions (mm) 500x450x224
Door hinge Right side
Color RAL 7035
IP class IP 54
Output 40A (MAGIC 340)

 

  • Advantages
  • Rugged design (IP54)
  • No subscription fees
  • Free log sheet service
  • Spike & Boost function for maximum protection with low copper consumption
  • Graphical overview 
  • Programmable operational presets
  • Control over both ICAF and ICCP systems
  • Remote access through website
  • Touchscreen 

 

ICAF/MGPS power unit for growth prevention in box coolers, open cooling systems and strainers using copper anodes. The controller has a self-testing and calibrating microprocessor. System will be operated by an external LCD touchscreen. The unit’s output can be adjusted with presets to suit operational conditions. It can interact with seawater pumps to save anode material.

General  
Article code MAGIC 310
Description MGPS System
Mounting type Wall mounted
Total weight (kg) About 25 kg
Cabinet dimensions (mm) 500x450x224
Door hinge Right side
Color RAL 7035
IP class IP 65
Input 110/230/440VAC – 1 phase
Output 10A
Number anodes Max 4

 

  • Advantages
  • Rugged design (IP65)
  • No subscription fees
  • Free log sheet service
  • Spike & Boost function for maximum protection with low copper consumption
  • Programmable operational presets
  • Graphical overview of vessel
  • Control over both ICAF and ICCP systems
  • Remote access through website
  • Touchscreen interface

ICAF/MGPS power unit for growth prevention in box coolers, open cooling systems and strainers using copper anodes. The controller has a self-testing and calibrating microprocessor. System will be operated by an external LCD touchscreen. The unit’s output can be adjusted with presets to suit operational conditions. It can interact with seawater pumps to save anode material.

General  
Article code MAGIC 320
Description MGPS Systems
Mounting type Wall mounted
Total weight (kg) About 25 kg
Cabinet dimensions (mm) 800x600x254
Door hinge Right side
Color RAL 7035
IP class IP 65
Input 110/230/440VAC – 1 phase
Output 20A
Number anodes Max 8

 

  • Advantages
  • Rugged design (IP65)
  • No subscription fees
  • Free log sheet service
  • Spike & Boost function for maximum protection with low copper consumption
  • Programmable operational presets
  • Graphical overview
  • Control over both ICAF and ICCP systems
  • Remote access through website
  • Touchscreen

ICAF/MGPS power unit for growth prevention in box coolers, open cooling systems and strainers using copper anodes. The controller has a self-testing and calibrating microprocessor. System will be operated by an external LCD touchscreen. The unit’s output can be adjusted with presets to suit operational conditions. It can interact with seawater pumps to save anode material.

General  
Article code MAGIC 330
Decription MGPS Systems
Mounting type Wall mounted
Total weight (kg) About 25 kg
Cabinet dimensions (mm) 500x450x224
Door hinge Right side
Color RAL 7035
IP class IP 65
Input 110/230/440VAC – 1 phase
Output 30A
Number anodes Max 12

 

  • Advantages
  • Rugged design (IP65)
  • No subscription fees
  • Free log sheet service
  • Spike & Boost function for maximum protection with low copper consumption
  • Programmable operational presets
  • Graphical overview
  • Control over both ICAF and ICCP systems
  • Remote access through website
  • Touchscreen

ICAF/MGPS power unit for growth prevention in box coolers, open cooling systems and strainers using copper anodes. The controller has a self-testing and calibrating microprocessor. System will be operated by an external LCD touchscreen. The unit’s output can be adjusted with presets to suit operational conditions. It can interact with seawater pumps to save anode material.

General  
Article code MAGIC 340
Description MGPS System
Mounting type Wall mounted
Total weight (kg) About 25 kg
Cabinet dimensions (mm) 500x450x224
Door hinge Right side
Color RAL 7035
IP class IP 54
Input 110/230/440VAC – 1 phase
Output 40A
Number anodes Max 16
  • Advantages
  • Rugged design (IP54)
  • No subscription fees
  • Free log sheet service
  • Spike & Boost function for maximum protection with low copper consumption
  • Programmable operational presets
  • Graphical overview
  • Control over both ICAF and ICCP systems
  • Remote access through website
  • Touchscreen

Contact us if you have questions or wish to receive a quotation

CONTACT US

  • What kind of objects can be protected with MME Group ICCP systems?

    Objects protected by our ICCP systems include:

    • Seagoing vessels (all ship types) 

    • Offshore platforms and rigs

    • Offshore Wind Farms (OWF)

    • Harbour quay walls

    • Jetties, docks and piers 

    • Locks and floodgates 

    • Pipelines

    • Other steel structures that are immersed in water

  • Why is an MME Group ICCP system the best choice?

    The quality and reliability of MME Group ICCP systems is confirmed by decades of flawless operation of more than 1100 systems installed on ships and other marine objects all over the world.

  • Where are MME Group ICCP systems produced?

    MME Group ICCP systems are engineered and manufactured at our head office production location in The Netherlands.

  • What is the difference between aluminium and zinc anodes?

    Aluminium has a higher potential difference with other metals than zinc. We recommend aluminium anodes in fresh water because fresh water has a higher electrical resistance than salt water. In saltwater, both aluminum and zinc anodes are suitable.

  • How many anodes do I need?

    The number and size of anodes required for sufficient protection depends on the size of the vessel or structure. If necessary, we can create a tailored anode plan for you. Contact us for more information.

  • Where are MME Group anodes produced?

    All zinc and aluminium MME Group anodes are produced in our fully owned ISO 9001 certified anode foundry which is located in Faversham (UK). Most anode types are kept in stock in our warehouse in the Rotterdam area which makes it possible to deliver to almost any location in Europe within a few days.